Pedrollo Pressure Boosting Sets, 2.2kW, 440L/min, CB2-CP25/200B

Pedrollo Pressure Boosting Sets, 2.2kW, 440L/min, CB2-CP25/200B
Pedrollo Pressure Boosting Sets, 2.2kW, 440L/min, CB2-CP25/200B

Pedrollo Pressure Boosting Sets, 2.2kW, 440L/min, CB2-CP25/200B

Product Code: CB2-CP25/200B
Availability: In Stock
Loading ...
Share:

PREFER CONTACT KENT

Model: CB2-CP25/200B (Two Single-stage Centrifugal Pumps)

Price inclusives 6%GST.
Description

  • COMBIPRESS are twin pump sets for water pressurisation, with a range to suit the requirements of domestic, civil agricultural and industrial applications.

Principle of Operation

  • COMBIPRESS pressure booster sets are pre-assembled ready for installation.
  • The sets operate as "duty-assist", with one or both pumps starting automatically in succession as demand for water increases.
  • This system is enery efficient as it only starts the pumps necessary to meet the demand.
  • The lead pump is alternated automatically by the control panel.

Use
Clean water and chemically non aggressive liquids:

  • Water Supply: pressure boosting for industry, condominiums, hotels, communities, water treatment plants, camping sites, schools, hospitals, barracks, etc.
  • Irrigation: football and sports, grounds, golf courses, agriculture and artical snow systems.

Construction Characteristics

  • PUMPS complete with suction  and delivery manifolds, ball valves and non-return valves.
  • BASE made of powder-painted metal sections.
  • Control systems PRE-INSTALLED on the delivery manifold, comparising of pressure gauge, connection for pressure vessel (not supplied), and two user adjustable pressure switches. The factory settings are shown in the following tables.
  • CONTROL PANEL with door interlocked power switch, low voltage pressure switch control circuit, automatic pump changeover, thermal motor protector and "anti-bounce" system to ensure that the pumps run for an acceptable period once started.
    • CB2m: Single Phase 230V - 50Hz including capacitor, and with integral thermal overload protection.
    • CB2: Three Phase 230/400V - 50Hz up to 4kW
                                        400/690V - 50Hz from 5.5 to 18.5kW

Specifications

Power   2.2 + 2.2 kW
Phase Three Phase
Max. Flow Rate 26.4 m³/h
Head 49 m
Max. Head 440 L/min
Pressure Switch Factory Setting (1 bar)    

3.5 ÷ 4.5

Pressure Switch Factory Setting (2 bar) 3 ÷ 4          